The record is made up of 1 file (73 folios). It was created in 1 Mar 1934-20 Jun 1950. It was written in English. The original is part of the British Library: India Office The department of the British Government to which the Government of India reported between 1858 and 1947. The successor to the Court of Directors. Records and Private Papers Documents collected in a private capacity. .

Transcription

This transcription is created automatically. It may contain errors.

Apply page layout

Estimates and Prices
Will be given on receipt of the following particulars :
1st.—The fall (in feet or inches), which can be obtained from the stream, lake, or other
source of supply.
2nd.—The height to which the water is to be forced above the level of the Hydram.
3rd.—The distance to which the water has to be forced.
4th.—The approximate quantity of water (in pints or gallons) falling per minute.
5th.—The number of gallons required to be raised per day of 24 hours.
6th.—The distance in which the working fall is obtained.
7th.— If a “ B ” Hydram be required, the depth and horizontal distance from the
Hydram to the clean water should be stated, unless the clean water will
gravitate to the level of the Hydram.
“A” HYDRAMS raise part of the same water that works them.
“ B ” HYDRAMS work with impure water, whilst raising pure water from aspring or
shallow well.
Additional Particulars required in cases where Hydrams are required
to replace Unsatisfactory Rams by other makers.
A large proportion of the Hydrams we supply are to replace Rams by other makers
which are not satisfactory, and which have been put in in the first place on account
of their low price.
In such a case we require the following information :—
1st.—The length and bore of the existing drive-pipe, and how long in use.
2nd.—The length and bore of the rising main, and how long in use.
In taking the working fall on an old Hydram it should be measured from the surface
of the water over the mouth of the drive pipe, to the escape outlet of the waste or “ pulse ”
valve of the Hydram.
We cannot quote Prices without first having the information asked for above.
Would-be purchasers are often surprised that our Catalogue does not give any
Prices, but it is almost impossible to do so.
The cost of a Hydram depends on at least four things, which are never the same in
two cases consecutively, that is on the working fall and quantity of driving water
available, height to force, and amount of water to be raised, and therefore it is next
to impossible to quote even approximate prices without at least having answers to
the questions Nos. 1, 2, and 5 above.
Inclusive Prices quoted for the Hydram with its drive and delivery pipes delivered
and fixed, including tanks, service pipes and fittings, cattle troughs, and drinking bowls.

About this item

Content

The file contains papers relating to electric water pumps for the Bahrain Political Agency An office of the East India Company and, later, of the British Raj, headed by an agent. .

The file includes correspondence between the Political Agent A mid-ranking political representative (equivalent to a Consul) from the diplomatic corps of the Government of India or one of its subordinate provincial governments, in charge of a Political Agency. , Bahrain, and the following: the State Engineer, Bahrain Government; the Secretary to the Political Resident A senior ranking political representative (equivalent to a Consul General) from the diplomatic corps of the Government of India or one of its subordinate provincial governments, in charge of a Political Residency. in the Persian Gulf The historical term used to describe the body of water between the Arabian Peninsula and Iran. ; Khalil bin Ibrahim Kanoo; Charles Dalyrmple Belgrave, Adviser to the Bahrain Government; John Blake Limited, Hydraulic Engineers; Ramchand Jethmal, Iron, Steel and Hardware Merchants; Sigmund Pumps Limited; and Worthington-Simpson Limited, Engineers.

It also includes: an illustrated catalogue for Water Supply by Blake’s Hydrams (folios 7 to 26); a sale catalogue for Sigma Type V High Pressure Multi-Stage Turbine Pumps (folios 42 to 47); and advertisements for Beresford-Stork Pumps (folio 27), Tangye ‘AR’ Type End Suction Centrifugal Pumps (folios 53 to 54), and Worthington Simpson Monobloc Centrifugal Pumps (folios 62 to 63).

Extent and format
1 file (73 folios)
Arrangement

The papers are arranged in chronological order from the front to the rear of the file.

Physical characteristics

Foliation: the main foliation sequence (used for referencing) commences at the front cover with 1, and terminates at the inside back cover with 75; these numbers are written in pencil, are circled, and are located in the top right corner of the recto The front of a sheet of paper or leaf, often abbreviated to 'r'. side of each folio. An additional foliation sequence is present in parallel between ff 2-54; these numbers are also written in pencil, but are not circled.

Written in
English in Latin script
View the complete information for this record

Use and share this item

Share this item
Cite this item in your research

'File 18/11 Buildings Repairs Agency Buildings – Correspondence re – Water pumps for the Bahrain Agency.' [‎13v] (26/150), British Library: India Office Records and Private Papers, IOR/R/15/2/1642, in Qatar Digital Library <https://www.qdl.qa/archive/81055/vdc_100054940248.0x00001b> [accessed 23 April 2024]

Link to this item
Embed this item

Copy and paste the code below into your web page where you would like to embed the image.

<meta charset="utf-8"><a href="https://www.qdl.qa/en/archive/81055/vdc_100054940248.0x00001b">'File 18/11 Buildings Repairs Agency Buildings – Correspondence re – Water pumps for the Bahrain Agency.' [&lrm;13v] (26/150)</a>
<a href="https://www.qdl.qa/en/archive/81055/vdc_100054940248.0x00001b">
	<img src="https://iiif.qdl.qa/iiif/images/81055/vdc_100000000282.0x000179/IOR_R_15_2_1642_0026.jp2/full/!280,240/0/default.jpg" alt="" />
</a>
IIIF details

This record has a IIIF manifest available as follows. If you have a compatible viewer you can drag the icon to load it.https://www.qdl.qa/en/iiif/81055/vdc_100000000282.0x000179/manifestOpen in Universal viewerOpen in Mirador viewerMore options for embedding images

Use and reuse
Download this image